Occlusion
Coltene Coltolux Led Light Cure
Coltene Coltolux Led Light Cure
Regular price
Rs. 30,199.00
Regular price
Rs. 42,336.00
Sale price
Rs. 30,199.00
Unit price
per
Tax included.
Couldn't load pickup availability
Features
- High output LED for fast cures. Cures 2 mm in only 10 s.
- Dome shaped lens minimizes light diffusion.
- LED light output matches the absorption spectrum of Camphorquinone (CQ) Photoinitiators.
- Audible signal every 10 s and automatic power saving sleep mode after 20 s of operation.
- Hundreds of 10-s cures with a fully charged power cell.
Description
The Coltolux® LED combines a slim curing probe with high output in a cordless lightweight penstyle design.
- High output LED for fast cures. Cures 2 mm in only 10 s.
- Dome shaped lens minimizes light diffusion.
- LED light output matches the absorption spectrum of Camphorquinone (CQ) Photoinitiators.
- Audible signal every 10 s and automatic power saving sleep mode after 20 s of operation.
- Hundreds of 10-s cures with a fully charged power cell.
- Test block provided for determining accurate cure times.
Indications for Use
The Coltolux® LED is indicated for the polymerization of intra and extra oral restorations fabricated from materials (commonly referred to as visible light cured dental restoratives and/or composites and/or dental adhesives) that contain Camphorquinone as the photoinitiator.
Direction to Use
SET-UP AND ASSEMBLY
- Remove the protective insert by first sliding the release button in the direction indicated by the arrow. Hold the button in this position while removing the insert from the supply.
- Angle the top of the new adapter into the recess of the supply. Slide the release button in the direction indicated while simultaneously pressing the new adapter into place.
- Insert the handpiece into the charger base. When the handpiece is being charged, the light on the charger base will be orange. When the handpiece is fully charged and ready, the orange light
on the charger base will turn green. The initial charging of the handpiece will require approximately 3 hours to fully charge. - When the handpiece is removed from the charger base the small light above the On/Off button on the handpiece will be green, indicating the unit is ready for use.
FUNCTION CHECK
-
Activate/Deactivate Light - Depressing the On/Off button on the handpiece activates or
deactivates the curing light. Do not hold the button continuously throughout the curing cycle. During operation an audible beep will be emitted every 10 seconds. The unit shuts off
automatically after 20 seconds. - Measuring the Light’s Effectiveness - To ensure complete polymerization at all times, it is critical to periodically test the light intensity output.
-
Radiometer Display - A reading of 300 mW/cm2 or higher indicates that the light output
is acceptable for the polymerization of material up to a 2.0 mm depth. Follow the dental material manufacturer’s instructions for recommended exposure time, and check using the supplied test block. A reading below 300 mW/cm2 or a reduction of intensity of the light output in comparison to the original value, indicates that corrective action should be taken.
CLINICAL APPLICATION
- Polymerization: Determine the exposure time in accordance with the dental material manufacturer’s instructions using the test block provided. If the exposure time exceeds 20 sec,
COLTENE recommends including a cooldown time before initiating another cycle. Failure to do so increases the risk of tissue burns and inadvertent heating of the dental pulp. - Remove the charged handpiece from the charger base; position the light shield; slide the single use barrier sleeve over the light; attach the light shield direct the tip of the light
lens as close to the restorative material as possible without touching. - Activate Coltolux® LED with a momentary push of the button. Avoid contact with un-polymerized restorative material, glass ionomer, liquid resin or bonding agent because direct
contact will cause these materials to adhere to the light lens. This will block the light transmission and result in improper polymerization. - To safely terminate procedure, press and release activation button